Hi all,
Besides the information provided in the
Courses, there were still lots of questions about resting-state fMRI data processing. Here we'd like to build a FAQ section for your convenience. However, the FAQ is just started and will be developed gradually.
Best,
Chao-Gan
1. What are the toolboxes needed for DPABI/DPARSF?
A: DPABI/DPARSF works well with MATLAB and Statistics Toolbox, Image Processing Toolbox and Signal Processing Toolbox. In addition, Parallel Computing Toolbox is needed if the users want to process multiple subjects in parallel computing mode.
2. How to solve the problem of “out of memory”?
3. What’s the ROI information of the templates provided in DPARSF?
4. Why the data after nuisance regression looks so strange (distorted)?
5. How to compare a single case with a group of controls?
6. Does the part "Reorienting T1 Image Interactively for XXX" require any input from the user?
7. What’s the input for smoothness estimation?
8. What’s the option of “IsTwoTailed” in GRF correction?
jia
Mon, 08/17/2020 - 14:10
Permalink
TFCE correlation
老师您好:
我是在做TFCE矫正的过程中出现了以下的报错,
错误使用 palm_takeargs (line 1133)
Unknown option: "Z:\data\rest\Hippocampus_FC\dpabi_analysis\349r\TFCE\Temp\Design.csv"
出错 palm_core (line 33)
[opts,plm] = palm_takeargs(varargin{:});
出错 palm (line 81)
palm_core(varargin{:});
出错 y_GroupAnalysis_PermutationTest_Image (line 102)
palm([TempDir,filesep,'PALMConfig.txt']);
出错 y_Correlation_Image (line 74)
y_GroupAnalysis_PermutationTest_Image(DependentVolume,Regressors,OutputName,MaskFile,CovariateVolume,Contrast,'T',0,Header,PALMSettings);
出错 DPABI_STAT_TOOL>ComputeButton_Callback (line 536)
y_Correlation_Image(S, SeedSeries, OutputName, MaskFile, ImageCell, TextCell, PALMSettings);
出错 gui_mainfcn (line 95)
feval(varargin{:});
出错 DPABI_STAT_TOOL (line 42)
gui_mainfcn(gui_State, varargin{:});
出错 @(hObject,eventdata)DPABI_STAT_TOOL('ComputeButton_Callback',hObject,eventdata,guidata(hObject))
Error while evaluating uicontrol Callback
我的DPABI版本是3.1,matlab2014a,想请教一下这种报错一般是什么原因,需要怎么处理?谢谢您的回复。
YAN Chao-Gan
Wed, 08/19/2020 - 09:03
Permalink
看不出来是什么原因。可以试试别的电脑,或者别的数据。
看不出来是什么原因。可以试试别的电脑,或者别的数据。
jia
Thu, 08/20/2020 - 03:47
Permalink
谢谢严老师的指导!
谢谢严老师的指导!
asus_learner
Fri, 06/18/2021 - 03:18
Permalink
你好!请问你的问题解决了吗
你好!请问你的问题解决了吗?我在校正过程中也出现了类似的问题,希望能够得到你的回复!感谢!
zhengyongze
Thu, 07/08/2021 - 05:11
Permalink
您好
你找到方法了吗?我也遇到了类似问题,恳请您的答复
zhengyongze
Thu, 07/08/2021 - 05:07
Permalink
遇到了同样的问题,同求解决方法,谢谢了
遇到了同样的问题,同求解决方法,谢谢了
zzq5819
Thu, 10/29/2020 - 03:48
Permalink
<div>Chris Rorden's dcm2niiX
<div>Chris Rorden's dcm2niiX version v1.0.20200331 (JP2:OpenJPEG) (JP-LS:CharLS) MSC1900 (64-bit Windows) </div><div>Warning: only processing last of 3 input files (recompile with 'myEnableMultipleInputs' to recursively process multiple files) </div><div>Error: Input folder invalid: stimulation\FunRaw\Sub_045\GUO_QINGQING.MR.SUS_HEAD.0011.0001.2020.09.14.15.09.58.997810.96394369.IMA </div><div>Converting Functional Images:Sub_045 OK</div><div> </div><div>严老师您好!我想请教下您,我为什么用dipabi 在第一步就报错 ,dicom 文件没法转成nifti 文件 FunImg文件夹为空,请指点!</div>
YAN Chao-Gan
Thu, 10/29/2020 - 04:29
Permalink
Please see here to check the
Please see here to check the errors: http://rfmri.org/DPABIErrorHandling
SiyiLi
Tue, 01/12/2021 - 09:22
Permalink
mayhappy
Fri, 04/23/2021 - 07:31
Permalink
做完AVCOVA之后在VIEWER加载结果出错
严老师您好,我做了三组数据的ANCOVA,然后用hsd做多重校正,得到的三组之间的对比,其中G1VSG2 G1VSG3,两个结果不能在VIEWER中显示,但是G2VSG3却可以正常显示,报错信息如下:
YAN Chao-Gan
Fri, 04/23/2021 - 09:52
Permalink
结果值里面有NaN?还是全0?
结果值里面有NaN?还是全0?
mayhappy
Sun, 04/25/2021 - 08:36
Permalink
Nmin还有Pmin是0,Nmax和Pmax都有数值
Nmin还有Pmin是0,Nmax有数值,colorbar值是12.
是看这个么?
两组不能加载的Pmax是inf,能加载的那组是数值,是因为这个缘故么?
YAN Chao-Gan
Tue, 05/11/2021 - 04:20
Permalink
那是因为有Inf值的出现
那是因为有Inf值的出现。仔细思考一下你的图像为什么会出现Inf值。
mayhappy
Sun, 05/16/2021 - 10:47
Permalink
数据整理、预处理都是按照严老师的视频来操作的
数据整理、预处理都是按照严老师的视频来操作的,还请严老师指教。谢谢!
luckyDog
Tue, 06/08/2021 - 08:39
Permalink
你好,我也遇到了这个问题,请问你找到原因并解决了吗
你好,我也遇到了这个问题,请问你找到原因并解决了吗
YAN Chao-Gan
Fri, 06/18/2021 - 09:02
Permalink
通常可能是你的数据有些问题,想办法查找一下。
通常可能是你的数据有些问题,想办法查找一下。
YAN Chao-Gan
Fri, 07/16/2021 - 04:54
Permalink
可能是那两组设置有问题,结果文件为空。
可能是那两组设置有问题,结果文件为空。
Jin Long
Wed, 05/26/2021 - 10:05
Permalink
repeated measures ANCOVA
严老师您好:
关于repeated measures ANCOVA在dpabi软件统计模块的使用中和ANCOVA有什么区别吗?例如只有一组病人治疗前后两个时间点的数据可以用repeated measures ANCOVA吗?我在使用这个模块时将两个时间点影像数据放进去可以出结果,但它这个和配对t检验有什么区别吗?
感谢老师
YAN Chao-Gan
Fri, 06/04/2021 - 04:14
Permalink
只有两个时间点用配对t检验。如果有3个时间点
只有两个时间点用配对t检验。如果有3个时间点,用repeated measures ANCOVA。
chenyuxinxin
Sun, 11/28/2021 - 05:39
Permalink
linux下dparsf运行出错
puyunfashi
Mon, 11/29/2021 - 03:45
Permalink
这个问题仅仅会影响pictures4checknormal
这个问题仅仅会影响pictures4checknormalization文件夹里面的图片,我的建议是无视这个问题,从FunImgARCW开始计算接下来的指标。
Frozen
Fri, 10/21/2022 - 18:01
Permalink
FieldMap Correction之后配准效果很差
严老师您好,我在对图像进行FirldMap Correction之后,图像被拉长,形状变得很奇怪,导致后面的配准效果很差,不知道这是什么原因导致的呢?以下是校正前后的影像,以及vdm5_scfpm_sc*.nii的图像:
YAN Chao-Gan
Sat, 12/31/2022 - 04:52
Permalink
感觉是fieldmap有问题?
感觉是fieldmap有问题?