Hi @all,
I have a question regarding the smoothing of RS fMRI data. I want to compare patiens and controls based on ALFF, fALFF, ReHO, VHMC and also want to use the extracted AAL ROIs to analyze each subject individually for calculating cross-correlation between ROIs. Now I was wondering if it is even necessary to apply smoothing to the data at all? I was also wondering if it is necessary to apply the head motion scrubbing regressors or if ths will corrupt the calculation of ALFF, fALL asf. ? Because as I understood scrubbing removes bad time points.
Can anyone help me out here?
greetings
David
YAN Chao-Gan
Sat, 02/21/2015 - 15:08
Permalink
Hi David,
Hi David,
For ReHo, smoothing in preprocessing should not be performed. For the others, you can smooth in preprocessing or after the derivatives were generated.
I don't recommend scrubbing for ALFF/fALFF analyses. For the others, supplementary analysis with scrubbing can be performed to confirm the main results.
Best,
Chao-Gan
David
Sat, 02/21/2015 - 16:09
Permalink
Thank you :). Is the
Thank you :). Is the scrubbing option in DPARSF the same as including the head motion scrubbing regressors? In other words, should I use neither of those options for ALFF/fALFF or can I use the head motion scrubbing regressors -option instead of the scrubbing option to get better data?
liuchen
Sun, 02/22/2015 - 04:09
Permalink
回复: [RFMRI] Group comparison,
YAN Chao-Gan
Sun, 02/22/2015 - 18:59
Permalink
Re: [RFMRI] Group comparison,
Scrubbing regressors are spike regression -> model the bad points in a regression model.
David
Tue, 02/24/2015 - 11:08
Permalink
Thank you :)
Thank you :)